Diagnostic channels and description of the old Klimatronic/STARA CLIMATE 1 system error no 2 actual value feelers (virtual) 3 actual value interior feeler console 4 actual value outside temperature - feeler wasserkasten 5 actual value outside temperature - feeler bumper 6 actual value blowing out feeler floor space 7 is value blowing out feeler Mannanstroemer 8 display checks 9 actual digital value acknowledging potentiometer temperature flap (numeric value) 10 target digital value temperature flap (numeric value) 11 actual digital value feedback A/C flap (numeric value) 12 target digital value A/C flap (numeric value) 13 is digital value acknowledging potentiometer Fuss/Def flap (numeric value) 14 target digital value Fuss/Def flap (numeric value) 15 actual digital value acknowledging potentiometers Stauluftklappe(Numeri value) 16 target digital value ram air flap (numeric value) 17 driving speed (km/h) 18 actual value of the blower tension (volt) 19 desired value of the blower tension (volt) 20 actual value of the generator/on-board tension (volt) 21 number of low-voltage events (not fluechig) (numeric value) 22 switching status of the high pressure switch 23 number of high pressure events (volatile) (numeric value) 24 number of high pressure events (non volatile) (numeric value) 25 A/D value kickdown switch 26 A/D value hot light 27 Motordrehzal (thousand U/min) 28 Generatordrehzal (thousand U/min) 29 coding 30 software-Version 31 software index 32 potentiometer error counters temperature flap (numeric who value) 33 potentiometer error counters A/C flap (numeric value) 34 potentiometer error counters Fuss/Def flap (numeric value) 35 potentiometer error counters ram air flap (numeric value) 36 Temperarturklappe notice cold (numeric value) 37 Temperarturklappe notice warm (numeric value) 38 A/C flap notice closed 39 A/C flap notice opened 40 Fuss/def flap notice Def 41 Fuss/def flap notice foot 42 ram air flap notice up 43 ram air flap notice too 44 operating cycle counters (numeric value) 45 interior temperature counted (Ninc) dig 46 outside temperature filtered (°C) 47 outside temperature not filtered (°C) 48 ECOR (?) 49 error counters Tachosignal (numeric value) 50 service life (minutes) 51 engine temperature (°C) (not oil!) 52 generator switching off conditions 53 announcement more actively el. Exits: Generator/circulating air valve/water valve (numeric value) 54 rule index (numeric value) 55 outside temperature (°C) 56 interior feelers (virtual) 57 interior feelers console (°C) 58 temperature wasserkasten (°C) 59 temperature bumper (°C) 60 blowing out feelers floor space (°C) 61 blowing out feelers Mananstroemer (°C) 62 sun intensity (W/m-1) 63 sun intensity more gefilter (W/m-1) 64 delta exhaust rise 65 delta A/C Klappenverschiebung 66 time constant/1.6 seconds. 67 cold weather starting correction 68 maximum correcting variable for i and p-portion 69 actual value blowing out feelers foot (cnts) 70 desired value blowing out being foot (cnts) 71 deviation (Epsilon) 72 portion (+ heat/- cool) Diagnostic channels and description of the new Klimatronic/NOWA CLIMATE 0 system error no 1 desired value of the blower tension (volt) 2 actual value of the blower tension (volt) 3 desired value Defklappe 4 scaled desired value Defklappe 5 scaled actual value of Defklappe 6 desired value foot/man branch Roman flap 7 scaled desired value foot/man branch Roman flap 8 scaled actual value of foot/man branch Roman flap 9 desired value ram air/circulating air flap 10 scaled desired value ram air/circulating air flap 11 scaled actual value of ram air/circulating air flap 12 desired value temperature flap left 13 scaled desired value temperature flap left 14 scaled actual value of temperature flap left 15 desired value temperature flap right 16 scaled desired value temperature flap right 17 scaled actual value of temperature flap right 18 driving speed (km/h) 19 engine speed (10 U/min) 20 software-Version 21 AUDI software indexing 22 Hella software indexing 23 coding 24 digital value outside temperature feeler bumper in cnts 25 outside temperature feelers bumper in °C 26 digital value outside temperature feeler wasserkasten in cnts 27 outside temperature feelers wasserkasten in °C 28 outside temperature for announcement in °C 29 outside temperature for compressor in °C 30 outside temperature for regulation in °C 31 relationship sun li/re and/or re/li 32 sun sensor left filtered 10 W/m. 33 sun sensor right filtered 10 W/m. 34 sun sensor on the left of not filtered 10 W/m. 35 sun sensor on the right of not filtered 10 W/m. 36 digital value desired value sinking as f (sun intensity, outside temperature) 37 blowing out temperature reduction on the left of f (sun intensity li/re) in 0,5 K 38 blowing out temperature reduction on the right of f (sun intensity li/re) in 0,5 K 39 digital value blowing out temperature man left in cnts 40 blowing out temperature man left in °C 41 digital value blowing out temperature man right in cnts 42 blowing out temperature man right in °C 43 digital value blowing out temperature foot left in cnts 44 blowing out temperature foot left in °C 45 digital value blowing out temperature foot right in cnts 46 blowing out temperature foot right in °C 47 on-board tension (clamp 15) in volts 48 counters for cut off processes clamp 87a 49 compressor switching off conditions 50 RCN left retards 51 RCN right retards 52 RCN left instantaneously 53 RCN right instantaneously 54 target blowing out temperature left 55 target blowing out temperature right 56 service life coolant temperature calculated 57 in °C 58 coolant temperature of the combination instrument in °C 59 Pull down bits 60 cold weather starting bit 61 interrupted cold weather starting (bit) 62 Zuheizer switching off conditions 63 digital value sun sensor left not filtered in cnts 64 digital value sun sensor quite not filtered in cnts 65 epsilon inside 66 innentemp_filt 67 tumbling compressor switching off conditions (1xx up-to-date) 68 Operating cycle counter 69 epsilon_ausblas_li 70 epsilon_ausblas_re 71 rcn_filterzeit 72 initial value coolant temperature of the combination instrument +40°C 73 high pressure events non volatile 74 i_anteil_li_xuc - 128 75 i_anteil_lre_xuc - 128 76 high pressure events volatilely 77 Idle filtering actively 78 timers for Idle filtering value * 50ms (engine temp 1) 79 filter time for interior filter value * 12sec (engine temp 2) key number for operatings mode and target temperature used 80 81 key number after 1.3 seconds after power on key number corrected 82 (receive 10 times correctly)