Diagnostic channels and description of the old Klimatronic/STARA CLIMATE

1 system error no
2 actual value feelers (virtual)
3 actual value interior feeler console
4 actual value outside temperature - feeler wasserkasten
5 actual value outside temperature - feeler bumper
6 actual value blowing out feeler floor space
7 is value blowing out feeler Mannanstroemer
8 display checks
9 actual digital value acknowledging potentiometer temperature flap (numeric
value)
10 target digital value temperature flap (numeric value)
11 actual digital value feedback A/C flap (numeric value)
12 target digital value A/C flap (numeric value)
13 is digital value acknowledging potentiometer Fuss/Def flap (numeric value)
14 target digital value Fuss/Def flap (numeric value)
15 actual digital value acknowledging potentiometers Stauluftklappe(Numeri
value)
16 target digital value ram air flap (numeric value)
17 driving speed (km/h)
18 actual value of the blower tension (volt)
19 desired value of the blower tension (volt)
20 actual value of the generator/on-board tension (volt)
21 number of low-voltage events (not fluechig) (numeric value)
22 switching status of the high pressure switch
23 number of high pressure events (volatile) (numeric value)
24 number of high pressure events (non volatile) (numeric value)
25 A/D value kickdown switch
26 A/D value hot light
27 Motordrehzal (thousand U/min)
28 Generatordrehzal (thousand U/min)
29 coding
30 software-Version
31 software index
32 potentiometer error counters temperature flap (numeric who value)
33 potentiometer error counters A/C flap (numeric value)
34 potentiometer error counters Fuss/Def flap (numeric value)
35 potentiometer error counters ram air flap (numeric value)
36 Temperarturklappe notice cold (numeric value)
37 Temperarturklappe notice warm (numeric value)
38 A/C flap notice closed
39 A/C flap notice opened
40 Fuss/def flap notice Def
41 Fuss/def flap notice foot
42 ram air flap notice up
43 ram air flap notice too
44 operating cycle counters (numeric value)
45 interior temperature counted (Ninc) dig
46 outside temperature filtered (°C)
47 outside temperature not filtered (°C)
48 ECOR (?)
49 error counters Tachosignal (numeric value)
50 service life (minutes)
51 engine temperature (°C) (not oil!)
52 generator switching off conditions
53 announcement more actively el. Exits: Generator/circulating air
valve/water valve
(numeric value)
54 rule index (numeric value)
55 outside temperature (°C)
56 interior feelers (virtual)
57 interior feelers console (°C)
58 temperature wasserkasten (°C)
59 temperature bumper (°C)
60 blowing out feelers floor space (°C)
61 blowing out feelers Mananstroemer (°C)
62 sun intensity (W/m-1)
63 sun intensity more gefilter (W/m-1)
64 delta exhaust rise
65 delta A/C Klappenverschiebung
66 time constant/1.6 seconds.
67 cold weather starting correction
68 maximum correcting variable for i and p-portion
69 actual value blowing out feelers foot (cnts)
70 desired value blowing out being foot (cnts)
71 deviation (Epsilon)
72 portion (+ heat/- cool)


Diagnostic channels and description of the new Klimatronic/NOWA CLIMATE

0 system error no
1 desired value of the blower tension (volt)
2 actual value of the blower tension (volt)
3 desired value Defklappe
4 scaled desired value Defklappe
5 scaled actual value of Defklappe
6 desired value foot/man branch Roman flap
7 scaled desired value foot/man branch Roman flap
8 scaled actual value of foot/man branch Roman flap
9 desired value ram air/circulating air flap
10 scaled desired value ram air/circulating air flap
11 scaled actual value of ram air/circulating air flap
12 desired value temperature flap left
13 scaled desired value temperature flap left
14 scaled actual value of temperature flap left
15 desired value temperature flap right
16 scaled desired value temperature flap right
17 scaled actual value of temperature flap right
18 driving speed (km/h)
19 engine speed (10 U/min)
20 software-Version
21 AUDI software indexing
22 Hella software indexing
23 coding
24 digital value outside temperature feeler bumper in cnts
25 outside temperature feelers bumper in °C
26 digital value outside temperature feeler wasserkasten in cnts
27 outside temperature feelers wasserkasten in °C
28 outside temperature for announcement in °C
29 outside temperature for compressor in °C
30 outside temperature for regulation in °C
31 relationship sun li/re and/or re/li
32 sun sensor left filtered 10 W/m.
33 sun sensor right filtered 10 W/m.
34 sun sensor on the left of not filtered 10 W/m.
35 sun sensor on the right of not filtered 10 W/m.
36 digital value desired value sinking as f (sun intensity, outside
temperature)
37 blowing out temperature reduction on the left of f (sun intensity li/re)
in 0,5 K
38 blowing out temperature reduction on the right of f (sun intensity li/re)
in 0,5 K
39 digital value blowing out temperature man left in cnts
40 blowing out temperature man left in °C
41 digital value blowing out temperature man right in cnts
42 blowing out temperature man right in °C
43 digital value blowing out temperature foot left in cnts
44 blowing out temperature foot left in °C
45 digital value blowing out temperature foot right in cnts
46 blowing out temperature foot right in °C
47 on-board tension (clamp 15) in volts
48 counters for cut off processes clamp 87a
49 compressor switching off conditions
50 RCN left retards
51 RCN right retards
52 RCN left instantaneously
53 RCN right instantaneously
54 target blowing out temperature left
55 target blowing out temperature right
56 service life
coolant temperature calculated 57 in °C
58 coolant temperature of the combination instrument in °C
59 Pull down bits
60 cold weather starting bit
61 interrupted cold weather starting (bit)
62 Zuheizer switching off conditions
63 digital value sun sensor left not filtered in cnts
64 digital value sun sensor quite not filtered in cnts
65 epsilon inside
66 innentemp_filt
67 tumbling compressor switching off conditions (1xx up-to-date) 68
Operating cycle counter
69 epsilon_ausblas_li
70 epsilon_ausblas_re
71 rcn_filterzeit
72 initial value coolant temperature of the combination instrument +40°C
73 high pressure events non volatile
74 i_anteil_li_xuc - 128
75 i_anteil_lre_xuc - 128
76 high pressure events volatilely
77 Idle filtering actively
78 timers for Idle filtering value * 50ms (engine temp 1)
79 filter time for interior filter value * 12sec (engine temp 2)
key number for operatings mode and target temperature used 80
81 key number after 1.3 seconds after power on
key number corrected 82 (receive 10 times correctly)